Modifying global threshold configuration – H3C Technologies H3C Intelligent Management Center User Manual

Page 75

Advertising
background image

61

{

Trigger Times—If you enable the Level-2 threshold, set an alarm trigger frequency in the Trigger

Times field. When the monitor index meets the level-2 threshold once, the field value increases
by 1. APM generates a level-2 threshold alarm if the monitor index meets the level-2 threshold for

the number of times specified by Trigger Times.

8.

Click OK.

Modifying global threshold configuration

To modify global threshold configuration of a monitor index:

1.

Click the Resource tab.

2.

Select Application Manager > Configurations from the navigation tree.
The Configurations page appears.

3.

Click Threshold Configuration.
The Global Threshold List appears.

4.

Click the Modify icon

for the threshold you want to modify.

The Modify Threshold page appears.

5.

Modify basic parameters of the monitor index as needed:

{

Application Type—Cannot be modified.

{

Application Unit—Cannot be modified.

{

Index—Cannot be modified.

{

Threshold Type—Cannot be modified.

{

Threshold Condition—Modify the threshold condition. The available options vary with the
monitor index type. For the Value type, options are Greater than or equal to and Less than or

equal to. For the String type, options are Include and Exclude.

{

Unit—Modify the threshold unit type. The value depends on the monitor index type. Some
indexes do not contain a unit type, such as the physical thread count of a .NET server.

You cannot modify the application type, application unit, index, and threshold type.

6.

Modify the level-1 threshold parameters for the monitor index.
APM generates a major alarm when the monitor index meets the level-1 threshold. If you enable
the Level-2 threshold, APM generates a major alarm when the monitor index meets the level-1

threshold but does not meet the level-2 threshold.

{

Enable Level-1 Threshold—Modify the level-1 threshold setting for the monitor index. You can

modify the level-1 threshold value or disable the level-1 threshold as needed.

{

Threshold—If you enable the Level-1 threshold, set a level-1 threshold value in the Threshold
field.

{

Trigger Times—If you enable the Level-1 threshold, set an alarm trigger frequency in the Trigger
Times field. When the monitor index meets the level-1 threshold once, the field value increases

by 1. APM generates a level-1 threshold alarm if the monitor index meets the level-1 threshold for

the number of times specified by Trigger Times.

7.

Modify the level-2 threshold parameters for the monitor index.
APM generates a critical alarm when the monitor index meets the level-2 threshold.

{

Enable Level-2 Threshold—Modify the level-2 threshold setting for the monitor index. You can
modify the level-2 threshold value or disable the level-2 threshold as needed.