H3C Technologies H3C Intelligent Management Center User Manual

Page 541

Advertising
background image

527

4.

Configure the following parameters:

{

IP Address—Enter the IP address of the host on which the FTP service application to be
monitored is installed. If the host is already added to the IMC platform, you can also click Select
and select the host in the Select Devices window. For information about selecting a host, see "

2

Quick start

." APM automatically checks the specified IP address and associates the application

monitor with the host managed in the IMC platform.

{

Name—Enter a unique application monitor name. H3C recommends using Application
name_host IP address
for naming the application monitor.

{

Description—Enter a description for the application monitor.

{

Username—Enter the FTP username.

{

Password—Enter the password of the FTP user.

{

Whether to Download File—Select Yes if you want to test the download function of FTP.
Otherwise, select No.

Remote Source File Name—Enter the test file name.

APM downloads the file from the root directory of the FTP server.

Local Source File Name—Enter the local test file name, which must contains the absolute
path of the file.

{

Whether to Upload File—Select Yes if you want to test the upload function of FTP. Otherwise,
select No.

Local Source File Name—Enter the local test file name, which must contains the absolute
path of the file.

Remote Source File Name—Enter the test file name.

APM uploads the file to the root directory of the FTP server.

{

Application Monitor Port—Enter the port on FTP. The default port is 21.

{

Traffic Collection Port—Enter the service port number for FTP. The default port is 21. This field
appears only when at least one probe is configured for APM.

{

Polling Interval (min)—Select a polling interval for the application monitor. Available options
include 1, 2, 3, 4, 5, 10, 20, and 30. The default polling interval is 5 minutes. A shorter polling
interval provides more accurate real-time data but consumes more system resources.

{

Contact—Enter the contact information, such as name, email address, and telephone number.
The default is the username of the operator who created the application monitor.

{

Related Applications—Add the application that the FTP service depends on. Enter the complete
or part of the application monitor name in the Search field at the top of the window, and click

Search. Select the application that the FTP service depends on, and then click OK.
Operating system applications, such as Windows, AIX, SCO UNIX, FreeBSD, OpenBSD,
HP-UX, Solaris, Mac OS, and Linux, cannot be selected. Operators can view all dependencies

of the application in the dependency topology. APM automatically adds the dependencies
between the FTP service and operating system applications by IP address and displays their

dependencies in the application topology.

{

Detect Application—Select this parameter if you want to enable application detection.
Application detection enables APM to verify connection to the application by using the previous

parameter settings, and to determine whether to add the application monitor based on the
verification result. APM adds the application monitor only when it can connect to the

application. When this parameter is not selected, APM adds the application monitor without

verifying the connection.

Advertising