Modifying an ftp service application monitor – H3C Technologies H3C Intelligent Management Center User Manual

Page 542

Advertising
background image

528

5.

Click OK.

Modifying an FTP service application monitor

Authorized users can modify all parameters except the IP address of an FTP service application monitor.

When the IP address of a monitored FTP host changes, authorized users must add a new application
monitor for the host. The new application monitor cannot inherit the history data from the previous

application monitor.
To modify an FTP service application monitor:

1.

Click the Resource tab.

2.

Select Application Manager > Application Monitor from the navigation tree.
The page displays all application types that can be monitored by APM.

3.

Click the Modify icon

for the FTP service application monitor you want to modify.

The page for modifying the FTP service application monitor appears.

4.

Modify the following parameters:

{

IP Address—Cannot be modified.

{

Name—Modify the unique application monitor name. H3C recommends using Application
name_host IP address
for naming the application monitor.

{

Description—Modify a description for the application monitor.

{

Username—Modify the FTP username.

{

Password—Modify the password of the FTP user.

{

Whether to Download File—Select Yes if you want to test the download function of FTP.
Otherwise, select No.

Remote Source File Name—Enter the test file name.

APM downloads the file from the root directory of the FTP server.

Local Source File Name—Enter the local test file name, which must contains the absolute
path of the file.

{

Whether to Upload File—Select Yes if you want to test the upload function of FTP. Otherwise,
select No.

Local Source File Name—Enter the local test file name, which must contains the absolute
path of the file.

Remote Source File Name—Enter the test file name.

APM uploads the file to the root directory of the FTP server.

{

Application Monitor Port—Modify the port on FTP. The default port is 21.

{

Traffic Collection Port—Modify the service port number for FTP. This field appears only when at
least one probe is configured for APM.

{

Polling Interval (min)—Select a polling interval for the application monitor. Available options
include 1, 2, 3, 4, 5, 10, 20, and 30 in minutes. A shorter polling interval provides more
accurate real-time data but consumes more system resources.

{

Contact—Modify the contact information, such as name, email address, and telephone
number.