Module Configuration Definitions

3.4.3 Setting Module Configuration Definitions

3-14

3

„

Configuration Information

This window consists of tab pages that define the slot details for the racks and the rack set-
tings.

A maximum of a 4-rack Machine Controller can be set using the CP-717, but the MP910 is
restricted to Rack 1settings. Racks 2 to 4 cannot be set.

The number of functional Modules (i.e., number of slots) that can be mounted to a rack is 9
maximum, but the MP910 is installed in a personal computer, so settings are limited to slot
04. Also, the Modules allocated to the slots cannot be changed.

Rack 1:

3.4.3 Setting Module Configuration Definitions

„

Configuration Rack Information and Slot Information

MP910 virtual racks are allocated to the tab page for Rack 1.

Slot 00

Slot 01

Slot 02

Slot 03

Slot 04

MP910

LOCAL I/O

HSTIF

UNDEFINED
(SVB-01)

UNDEFINED
(SVB-01)

Setting Item

Details

Select Rack,
Rack Kind

The MP910 is automatically set to Rack 1 and a short rack.

No.

This number shows the slot numbers in the rack.

Module

Automatically set using the Module name set in the slots.

Control CPU No

The MP910 CPU is set automatically to 01.

Cir No.

In the MP910, LOCAL I/O and HSTIF Modules are automatically
set to 01.

Module (Dual)

The Dual Modules Setting is not supported in the current version.

Cir (Dual)

Dual Transmission Paths Setting is not supported in the current ver-
sion.

Replacement

Hot Swapping (removal/insertion under power) is not supported in
the current version.

I/O Start Register

Refer to LOCAL I/O and SVB-01 settings.

I/O End Register

Refer to LOCAL I/O and SVB-01 settings.

Input DISABLE

Sets to enable/disable inputs.
Blank: Enable/disable, D: Disabled, E: Enabled

Output DISABLE

Sets to enable/disable outputs.
Blank: Enable/disable, D: Disabled, E: Enabled

Motion Start Register

This is set automatically.

Motion End Register

This is set automatically.

Detail

Performs MECHATROLINK communications definitions for SVB-
01.

Status

This is not currently supported.