3.5 MP920 Module Definitions

3-61

3

All of the data listed above will be displayed in online mode. None will be displayed in
offline mode.

Error Status

Displays the details on the error when an error has occurred in trans-
mission status.
The following table lists the error status.

Status Value

Meaning

0

No error

1

System error

2

Local station port number setting error

3

System error (TCP settings)

4

System error (TCP settings)

5

Connection error (TCP settings)

6

System error

7

Data send error (TCP settings)

8

Data send error (TCP settings)

9

Data reception error (TCP settings)

10

Data reception error (TCP settings)

11

System error

12

Data conversion error (MEMOBUS and
MELSEC settings)

Send Count

Displays the number of data (number of packets) sent to the remote
station.

Receive Count

Displays the number of data (number of packets) received from the
remote station.

Error Count

Displays the number of times that an error has occurred.

Response Time
[ms]

Displays the time taken for a response to be received after a com-
mand was sent with the MSG-SND function.

Connection

Displays the Connect Type (connection type) set in the Transmission
Parameters Tab.

Protocol Type

Displays the Protocol Type set in the Transmission Parameters Tab.

Code

Displays the Code (data format) set in the Transmission Parameters
Tab.

DST. Station

Displays the DST. Station name (remote station name) set in the
Transmission Parameters Tab.

Setting Item

Details