4.3 Scan Time Definitions

4-11

4

4.3 Scan Time Definitions

This section explains how to set the scan times.

The scan times are the cycles repeated by Machine Controller to execute the user programs
(high-speed scan program, low-speed scan program) over and over. The MP940 also features a
system scan to enable high-precision servo control.

All three scan times must be set for the MP940: High-speed, low-speed, and system. The scan
time settings are important factors in MP940 operation. Refer to the MP940 Machine Controller
User's Manual: Design and Maintenance
(SIEZ-C887-4.1) and be sure that suitable times are
set.

4.3.1 Opening the Scan Time Window

Open the Scan Time Window according to instructions in 4.1.2 Opening System Configura-
tion Definitions Windows
.

„

Login Information

Login information is displayed below the title bar in the System Configuration Window.

Hyphens will be displayed in offline mode.

Information

Details

PT#

Displays the communications logical port.

UT#

Displays the unit number of the MP900-series Machine Controller.
The unit number is always 1.

CPU#

Displays the number of the CPU which was logged onto. The CPU
number is always 1.