3.5 MP920 Module Definitions

3-69

3

• I/O Allocation Using Network Configuration Information

When using the 260IF as a DeviceNet master, the settings can be configured based on
the I/O sizes read from the slaves.

To read the I/O sizes from the slaves, use the network configuration information read
function.

For setting method details, refer to 6.1 Reading Network Configuration Information
in the MP920 Machine Controller User's Manual: 260IF DeviceNet (SIEZ-C887-
5.2).

If allocating I/O using the network configuration information, delete the I/O allocation from all the
slaves before performing allocation.

3.5.11 Local I/O Definitions

This section explains how to set Local I/O Definitions.

„

Outline of the Local I/O Definitions

The LIO-01 Module is equipped with 32 digital inputs (DI) and 32 digital outputs (DO). I/O
servicing is performed at fixed intervals, once for each high-speed scan or low-speed scan in
the MP920 CPU Module.

Four digital inputs can be used as interrupts by enabling interrupts in the Module Configura-
tion Definitions Window.

The Local I/O Definitions Window sets the scan timing and assigns registers to the discrete
inputs and outputs (16 of each) in connectors CN1 and CN2.

INFO

I/O Type

CN1

CN2

Discrete Input

16 inputs

16 inputs

Discrete Output

16 outputs

16 outputs