Setting 217if transmission definitions – Yaskawa MP900 Series Machine Controller for Standard Operation User Manual

Page 144

Advertising
background image

3.5 MP920 Module Definitions

3-49

3

„

Setting 217IF Transmission Definitions

This section explains the various parameters required to use the 217IF transmission system.

The 217IF has tabs for the current circuit and the next two circuits. Click another circuit's tab
to switch to that circuit's Transmission Parameters Window.

The numbers displayed in the tabs at the top of the window (CIR#nn) are the 217IF Module
circuit numbers. Each 217IF Module requires 3 circuits and the same circuit number must

not be used more than once.

Machine Controller

Circuit Numbers

MP920

1 to 25

Setting Items

Details

Transmission Protocol

Select the desired protocol.

• MEMOBUS:

Yaskawa's standard MEMOBUS protocol.

• MELSEC:

Mitsubishi's special protocol (control protocol
type 1) for use with general-purpose sequencers
and computer links.

• OMRON:

OMRON's SYSMAC C-series Host Link proto-
col.

• No protocol:

Data can be transferred at any time by the user
application program.

Master/Slave

When the Transmission Protocol has been set to MEMOBUS,
MELSEC, or OMRON, select whether the Machine Controller will
operate as a Master or a Slave.

Device Address

Select the device address. When the Machine Controller is being
used as a Master, set the device address to 0. When the Machine
Controller is being used as a Slave, set the device address to a value
between 1 and 63.

Serial I/F
(Serial Interface)

Select the serial interface.

Transmission Mode

Select the transmission mode.

• RTU:

Specifies RTU mode when the Transmission Protocol is
set to MEMOBUS.

• ASCII: Specifies ASCII mode when the Transmission Protocol is

set to MEMOBUS.

• None:

Use for MELSEC, OMRON, and no-protocol transmis-
sions.

Data Length

Select the number of bits in one character.

• 8Bit: 8 bits
• 7Bit: 7 bits

Parity Bit

Specify whether or not the parity bit will be used.

• Even: Even parity
• Odd: Odd parity
• None: No parity check

Stop Bit

Select the number of stop bits.

• 1stop: 1 stop bit
• 2stop: 2 stop bits

Baud Rate

Select the transmission speed (bps).