Module Configuration Definitions

3.5.9 218IF Transmission Definitions

3-54

3

1 The address is made up of 32 bits, as shown in the following diagram. The 4 bytes (8 bits each) are sep-

arated by periods and the byte values are input in decimal.

The bytes are handled as 4 fields: Field No. 1 through Field No. 4 from the most-significant byte
through the least-significant byte.

The input ranges are different for each field:

• Field No. 1: 0 to 255 (excluding 127)
• Field No. 2: 0 to 255
• Field No. 3: 0 to 255
• Field No. 4: 1 to 254

2 We recommend IP addresses 192.168.1.1 through 192.168.1.254 as private addresses, but contact your

company's system administrator for confirmation.

Code

Input the data format that matches the format set in the remote sta-
tion.

• RTU:

Specifies RTU mode when MEMOBUS protocol is being
used.

• ASCII: Specifies ASCII mode.
• BIN:

Specifies binary mode.

The codes that can be selected depend on the data in the Protocol
Type field. The codes that can be selected are shown below.

Protocol

Selected

Data Code

RTU

ASCII

BIN

Extended
MEMOBUS

No

Yes

Yes

MEMOBUS

Yes

Yes

No

MELSEC

No

Yes

Yes

No protocol

No

Yes

Yes

DST. Station (Remote
Station's Name)

Input a station name (comment) for the remote station. The station
name can be up to 32 characters.

Setting Item

Details