Module Configuration Definitions

3.7.11 260IF Setup

3-158

3

3.7.11 260IF Setup

Perform the setup for the 260IF from the CP-717 Engineering Tool.

„

Opening the 260IF Definitions Window

The procedure to open the 260IF Definitions Window is given below.

1. Double-click the Module configuration definitions of the controller mounting the 260IF.

The Module Configuration Definitions Window will be displayed.

Fig 3.28 MP940 Module Configurations Window

With the MP940, the 260IF is allocated to slot 06 and this cannot be changed; select the
260IF Module.

The I/O leading and ending register addresses must be set in the 260IF Module settings.
Allocate the I/O register addresses to be used within the ranges shown below.

2. Double-click the slot set for the 260IF Module to open the 260IF Definitions Window.

No.




00

MP920

・・・

・・・

・・・

・・・

RESERVED

01

・・・

・・・

・・・

・・・

06

260IF

・・・

・・・

・・・

・・・

・・・

・・・

・・・

SERIAL

02

・・・

・・・

・・・

・・・

LIO

03

・・・

・・・

・・・

・・・

SVA

04

・・・

・・・

・・・

・・・

CNTR

05

・・・

・・・

・・・

・・・

Rack 1

Module
Control CPU Number

I/O Start Register
I/O End Register

MP940

I/O Leading Register (IW/OW Register Start
Offset)

0000 to 07FF

I/O Ending Register (IW/OW Register End
Offset)

0000 to 07FF