Module Configuration Definitions

3.5.20 MECHATROLINK Definitions

3-106

3

Refer to MP920 Machine Controller User's Manual: Design and Maintenance (SIEZ-C887-2.1) or
MP920 Machine Controller User's Manual: Motion Module
(SIEZ-C887-2.5) for details on monitor
parameter settings.

„

Saving, Deleting, and Closing the SVB Motion Parameters

Refer to the procedures in 3.3 Basic Individual Module Definition Operations for details.

1 This operation deletes the SVA motion fixed parameters and setting parameters of all axes.

2 The edited motion fixed parameters cannot be saved if the RUN (Servo ON) Flag is ON. Save the

motion parameters data after this flag has gone OFF.
The RUN (Servo ON) Flag is bit 0 of parameter number 2 (RUN Command Settings) in the Set Up
Parameters Tab. The register number for parameter 2 is OWC001.

3 The Save (S) command saves the motion fixed parameters for all axes of the servo number currently

being displayed.

4 The Error Detection Message Box is displayed if the data was not saved successfully. Refer to Appen-

dix A Error Messages, eliminate the cause of the error, and save the data again.

3.5.20 MECHATROLINK Definitions

This section explains how to set the MECHATROLINK Definitions.

„

Outline of the MECHATROLINK Definitions

To set the motion parameters, the required data must be set in three tab pages: The Trans-
mission Parameters Tab
, I/O Assignment Tab, and I/O Map Tab.

The status of transmissions can be monitored in the Status Tab.

Setting Item

Details

Axis Number

Select the desired axis number (axis 1 or axis 2). The parameters for
each axis are displayed.

SERVOPACK

Displays the type of SERVOPACK.

No.

Displays the parameter number of the parameter.

Parameter Name

Displays the parameter name.

REG-No.

Displays the number of the register that corresponds to the parameter
name.
The range of registers depends on the motion number and axis num-
ber currently being displayed.

Monitor Data

In online mode, the current values of the parameters are displayed.
In offline mode, nothing will be displayed.

Unit

Displays the units of the corresponding parameter.