Yaskawa MP900 Series Machine Controller for Standard Operation User Manual
Page 470

7.6 Tools
7-103
7
Setting Disable Coil Lists
Specifying Search Program Ranges
Drawing and function main programs, as well as SFC action blocks (online only) can be
searched.
Setting
Explanation
Ref. DWG
Specify the range of programs to search. Refer to Specifying Search
Program Ranges following this table.
Search Execute Button Executes the search.
No.
Displays the line number.
DWG/FUNC
Displays the drawing number or function symbol using the disabled
coil.
STEP
Displays the step number with the disabled coil. Refer to Step Num-
bers following this table.
RELAY
Displays the relay number of the disabled coil.
DIS
Displays the status of the disabled coil.
ON: Disabled coil is ON
OFF: Disabled coil is OFF
Comment
Displays the relay number comment.
Search Range
Details
*
Searches all drawings.
L
Searches the parent low-speed drawing.
L*
Searches all low-speed drawings.
L10*
Searches drawing L10 and all grandchild drawings of L10.
L10.*
Searches all grandchild drawings of L10.
L10.01
Searches the specified drawing.
F*
Searches all user functions.
FUNC001
Searches the specified user function.