3.7.6 Serial Transmission Definitions

3-138

3

Tab Pages

Use the tab pages to set the parameters for the Serial Module. There are two tab pages, one

for each port.

When the Serial Definitions Window is opened without any settings having been made previously, a
Create New Message Box will be displayed. Click the OK Button to proceed to the next operation.

„

Serial Communications Definitions

Two CIR# definition tabs are displayed in the Serial Definitions Window. Make the defini-
tions while switching between the tabs as required.

CP-217 Transmission Definitions

The definitions for CP-217 transmission are listed in the following table.

Tab Page

Details

CIR#01

Sets the RS-232C transmission parameters.

CIR#02

Sets the RS-422/485 transmission parameters.

Setting Item

Details

Circuit Number

Select the CIR# for the tab page.

Transmission Protocol

Select from MEMOBUS, MELSEC, or no protocol.

Master/Slave

Select whether the Module is a master or a slave.

Device Address

Set the master’s address to 0, and slave addresses from 1 to 63.

Serial I/F

Select RS-232 (RS-232C), RS-485, or RS-422.

Transmission Mode

Select from RTU, ASCII, or none.

Data Length

8Bit: 8 bits; 7Bit: 7 bits

Parity Bit

Select even, odd, or none (no parity).

Stop Bit

1stop: 1 stop bit; 2stop: 2 stop bits

Baud Rate

Select the transmission speed (bps).

Sending (Send Delay)

Set the delay between executing the send/receive functions (MSG-
SND OR MSG-RCV) and sending the message.

Automatically
Reception
(Automatic Reception)

Set whether or not to automatically respond to quires from the mas-
ter.

Readout of Input Relay Set the leading address and range of the input relays that can be read

for automatic response.

Readout of Input
Registers

Set the leading address and range of the input registers that can be
read for automatic response.

Readout/Write-in of
Coil

Set the leading address and range of the coils that can be read/written
for automatic response.

Readout/Write-in of
Hold Register

Set the leading address and range of the holding registers that can be
read/written for automatic response.