Table A.4 CPHD_DRV_nnn

No free program memory space
(CPDH_CPU_0B3)

There is no free program memory
space.

• Compress memory from the System Defini-

tion Window.

• Reduce the size of all drawing and program

memory areas.

• Delete unused drawings or functions.
• Reduce the number of steps in each drawing

and function.

• Reduce the number of # registers in each

drawing and function.

• Reduce the number of symbols in each

drawing and function.

• Reduce the number of comments in each

drawing and function.

Another drawing or function calling the
function to be deleted
(CPDH_CPU_0C0)

Another drawing or function calls
the function that is being deleted.

Delete the instruction that is calling the func-
tion to be deleted, and then delete the func-
tion.

Data trace cannot be executed because
trace definition data number set to 0
(CPDH_CPU_0C1)

Data trace cannot be executed
because the trace definition data
number is set to 0.

Reset the trace definitions.

Disable coil number exceeded maximum
(100)
(CPDH_CPU_0C2)

The maximum number of disabled
coils (100) has been exceeded.

Reduce the number of disabled coils.

Flash memory write failure
(CPDH_CPU_0C3)

The write to flash memory pro-
cessing failed.

Repeat the operation.
Replace the Machine Controller if the error
persists.

Program write-protected
(CPDH_CPU_0F0)

The program is currently write-
protected.

Set the program to write-enabled mode using
the System Configuration Window.

Program memory not initialized
(CPDH_CPU_0F1)

The program memory has not
been initialized.

Clear the memory or perform batch load oper-
ation.

Program write-protected
(CPDH_CPU_0F0)

Program write protection in the
system definitions are set to dis-
able writing.

Change the write-protection setting in the
System Definitions Window and retry the
operation.

Error Message

Probable Cause

Possible Correction

Error Message

Probable Cause

Possible Correction

Interrupt level exceeds 0x0f.
(CPDH_DRV_002)

The designated interrupt level
range of 0 to 16 in the systems
definition file has been exceeded.

Set the interrupt level to between 0 and 16.

215IF I/F DIP switch 2 error
(CPDH_DRV_003)

There is an shared memory
address error in the system defini-
tions file.

Set a correct shared memory address.

Designated port number exceeds 1 to 6
range
(CPDH_DRV_005)

The designated port number is
greater than the range of 1 to 6.

Designate a correct port number.

215IF I/F DIP switch 3 error
(CPDH_DRV_007)

There is an shared memory
address error in the system defini-
tions file.

Set a correct shared memory address.