background image

Module Configuration Definitions

3.7.8 SVA Parameter Settings

3-146

3

Refer to MP930 Machine Controller User

'

s Manual: Design and Maintenance (SIEZ-C887-1.1) for

details on servo parameter settings.

SERVOPACK Parameters Tab Page

Click the SERVOPACK Tab.

Refer to 6.4 Parameters for SGDH SERVOPACK in the MP940 Machine Controller User's
Manual: Design and Maintenance
(SIEZ-C887-4.1) for details on servo parameter settings.

„

Motion Monitor Tab Page

Click the Monitor Tab. The settings cannot be changed in this window.

Setting Item

Details

Axis Number

Displays the axis number. The axis is fixed at Axis 1.

No.

Displays the number of the servo parameter.

Parameter Name

Displays the parameter name.

Input Data (Set Data)

Input (or select) the value for the parameter. Refer to the list of
motion SERVOPACK parameters for details.

Unit

Displays the unit for setting the data.

Current Value

In online mode, the parameter's current value will be displayed. In
offline mode, nothing will be displayed.