3.5 MP920 Module Definitions

3-89

3

Table 3.14 Comparison of the SVA-01 and SVA-02 Modules

„

Opening the SVA Motion Parameters Window

Open the SVA Definitions Window according to the procedure in 3.3 Basic Individual Mod-
ule Definition Operations
. The Fixed Parameters Tab Page will be displayed first.

Item

4-axis Module (SVA-01)

2-axis Module (SVA-02)

Size

2-slot

1-slot

Number of Axes
Controlled

4 axes

2 axes

Analog Outputs

For speed reference:
PWM 16 bits, 4 channels
For torque reference: None

For speed reference:
PWM 16 bits, 2 channels
For torque reference:
D/A 12 bits, 2 channels

Analog Inputs

None

16 bits, 2 channels

Pulse Inputs

Phase-A/B/C inputs, 4 channels

Phase-A/B/C inputs, 2 channels

DI

3 inputs x 4 channels

DI0: SV RDY
DI1: SV ALM
DI2: BRK

(5 points + PI latch input) x 2 channels

DI0: General-purpose (RDY)
DI1: General-purpose (ALM)
DI2: General-purpose (ZERO)
DI3: General-purpose (OTF)
DI4: General-purpose (OTR)
DI5: PI latch

DO

6 outputs x 4 channels

DO0: SVON
DO1: SV ALM-RST
DO2: SV PCON
DO3: SV SEN
DO4: OTF
DO5: OTR

6 outputs x 2 channels

DO0: SV ON
DO1: General-purpose

(ALM-RST)

DO2: General-purpose (PCON)
DO3: SV SEN
DO4: General-purpose
DO5: General-purpose

External Inputs

6 inputs x 4 + 1 RCI input

(OTF, OTR, DEC,
ZERO, EXT,
RI) x 4
(RCI) x 1

(An PI latch is possible with

ZERO and EXT.)

None

External Outputs

2 outputs x 4 + 1 RCO output

(BRK, RO) x 4
(RCO) x 1

None