5.3 Creating Motion Programs

5-13

5

2. Point at the Motion Folder, click the right mouse button, and select Open (O) and then

Resister Writing Permission (R) from the pop-up menu.

The Register Write Enable Setting Window will open.

The Resister Writing Permission Window can also be opened by selecting File (F), Open (O), and then
Resister Writing Permission (R) from the menu.

„

Setting Register Write Enable Setting Properties

M and O Registers

Input the range of register numbers that can be used in the motion programs. Input M regis-
ter number in decimal and O register number in hexadecimal. The default range will be from
0 to the highest register number. The highest register number depends on the model.

User Permissions

Set the user permissions required to set the enabled ranges. Any user with permissions lower
than the value set here will not be able to set values.

Setting Parameters

Click the Set Button to enable the set values.

MW

DEC)

OW

HEX)

×

Setup of register writing permission

Setup of the range of the register which permits writing in the

motion program.

M registers

O registers

User permissions

Set

Reset

Close

to

to