3.4 MP910 Module Configuration Definitions

3-15

3

„

Setting Ranges for the MP910 I/O Start/End Register Numbers

1 0000 to 13FF hex (5,120 words total)

Be sure that the register numbers set for each Module do not overlap with any other Module's register
numbers.

2 With the MP910, standard register numbers have been set for each Module. We recommend using

these standard register number settings.

• LOCAL I/O: 0000 to 0001
• SVB-01: 0100 to 04FF (slot 03)

0500 to 08FF (slot 04)

Automatically set items cannot be changed.

„

Saving, Deleting, and Closing Module Configuration Definitions

For the saving, deleting, and closing procedures, refer to 3.3 Basic Individual Module Defi-
nition Operations
.

3.4.4 Opening Individual Module Configuration Definitions Window

Set the individual Module definition data for the MP930 using the procedure in 3.3 Basic
Individual Module Definition Operations
. Refer to the following for individual Module set-
ting data.

• LOCAL I/O definitions
• SVB-01 definitions

3.4.5 Local I/O Definitions

This section explains the local I/O definitions that are set for virtual slot 01.

„

Opening the Local I/O Definition Window

Open the following window by referring to 3.3 Basic Individual Module Definition Opera-
tions
.

INFO

MP910

JEPMC-MC100/
JEPMC-MC150

CN1

CN2

I/O port

(LOCAL I/O)