4 Motion Parameters

4.1.2 SVA-01 Module Motion Parameter Register Numbers

4-4

4.1.2 SVA-01 Module Motion Parameter Register Numbers

The motion parameter register numbers (I or O register numbers) are determined by the module
number and axis (axes 1 to 16).

Motion parameter register numbers can be obtained using the following equation.

Motion parameters register number =

I(O)W 8000 + (Module number

− 1)

×

800 hex + (Axis number

− 1)

×

80 hex

The following tables lists the motion parameters register numbers.

The maximum number of axes that can be allocated per Module differs for the MP2300 and MP2200.
The maximum numbers of axes are given in the following table.

Module No.

Axis No. 1

Axis No. 2

1

8000 to 807F

8080 to 80FF

2

8800 to 887F

8880 to 88FF

3

9000 to 907F

9080 to 90FF

4

9800 to 987F

9880 to 98FF

5

A000 to A07F

A080 to A0FF

6

A800 to A87F

A880 to A8FF

7

B000 to B07F

B080 to B0FF

8

B800 to B87F

B880 to B8FF

9

C000 to C07F

C080 to C0FF

10

C800 to C87F

C880 to C8FF

11

D000 to D07F

D080 to D0FF

12

D800 to D87F

D880 to D8FF

13

E000 to E07F

E080 to E0FF

14

E800 to E87F

E880 to E8FF

15

F000 to F07F

F080 to F0FF

16

F800 to F87F

F880 to F8FF

MP2000 Series

Number of

Modules

Maximum Number

of Axes

MP2300

0 to 2

4 axes

MP2200

1-rack configuration

0 to 7

14 axes

2-rack configuration

0 to 14

28 axes

3-rack configuration

0 to 16

32 axes

4-rack configuration

INFO