Yaskawa MP2200 Machine Controller User Manual

Page 432

Advertising
background image

8 SVR Virtual Motion Module

8.2.2 Motion Parameter Settings

8-16

[ j ] Position Information

[ k ] SERVOPACK Information 2

[ l ] Supplemental Information

IL††0E

Machine Coordinate Target Position (TPOS)

Range

Unit

−2

31

to 2

31

−1

Reference unit

Stores the target position in the machine coordinate system managed by the Motion Module.

IL††10

Target Position (CPOS)
Range

Unit

−2

31

to 2

31

−1

Reference unit

Stores the calculated position in the machine coordinate system managed by the Motion Module.

IL††12

Machine Coordinate System Position (MPOS)
Range

Unit

−2

31

to 2

31

−1

Reference unit

Stores the reference position in the machine coordinate system managed by the Motion Module. MPOS is always equal to CPOS.

IL††16

Machine Coordinate Feedback Position (APOS)

Range

Unit

−2

31

to 2

31

−1

Reference unit

APOS is always equal to CPOS.

IL††1C

Target Position Difference Monitor

Range

Unit

−2

31

to 2

31

−1

Reference unit

Stores the target position difference managed by the Motion Module.

IW††1E

POSMAX Number of Turns

Range

Unit

−2

31

to 2

31

−1

rev

This parameter is valid for an infinite length axis.
The count stored in this parameter goes up and down every time the current position exceeds the Maximum Value of Rotary
Counter (POSMAX) (fixed parameter 10).

IL††40

Feedback Speed

Range

Unit

−2

31

to 2

31

−1

Depends on speed unit

(OW††03 bits 0 to 3).

Stores the feedback speed.

IL††42

Torque (Thrust) Reference Monitor

Range

Unit

−2

31

to 2

31

−1

0.01%, 0.001%

Stores the value of the torque reference.

IL††56

Fixed Parameter Monitor

Range

Unit

−2

31

to 2

31

−1

Stores the data of the specified fixed parameter number.

Advertising