4.2 Motion Parameter Lists

4-9

OW††08

Motion Command

0: NOP
1: POSING
2: EX_POSING
3: ZRET
4: INTERPOLATE
5: ENDOF_INTERPOLATE
6: LATCH
7: FEED
8: STEP
9: ZSET

Yes

Yes

Yes

10: ACC
11: DCC
12: SCC
13: CHG_FILTER
14: KVS
15: KPS
16: KFS
17: PRM_RD
18: PRM_WR
19: ALM_MON
20: ALM_HIST
21: ALMHIST_CLR
22: ABS_RST

Yes

Yes

23: VELO
24: TRQ
25: PHASE

Yes

Yes

Yes

26: KIS

Yes

Yes

OW††09

Motion Command Control
Flags

Bit 0: Command Pause (0: OFF/1: ON)

Yes

Yes

Yes

Bit 1: Command Abort (0: OFF/1: ON)

Yes

Yes

Yes

Bit 2: JOG/STEP Direction (0: Forward rotation/1: Reverse
rotation)

Yes

Yes

Yes

Bit 3: Home Direction (0: Reverse rotation/1: Forward rotation)

Yes

Yes

Bit 4: Latch Zone Enable (0: Disabled/1: Enabled)

Yes

Yes

Bit 5: Position Reference Type
(0: Incremental Addition Mode/1: Absolute Mode)

Yes

Yes

Yes

Bits 6 to F: Reserved

OW††0A

Motion Subcommand

0: NOP

Yes

Yes

Yes

1: PRM_RD
2: PRM_WR
3: Reserved
4: SMON

Yes

5: FIXPRM_RD

Yes

Yes

Yes

OW††0B

Reserved

OL††0C

Torque Reference

Unit is according to OW††03, bits 12 to 15 (Torque Unit).

Yes

Yes

Yes

OW††0E

Speed Limit during Torque
Reference

1 = 0.01% (percentage of rated speed)

Yes

Yes

OW††0F

Torque Reference Primary
Lag Filter

1 = 1 ms

Yes

OL††10

Speed Reference

Unit is according to OW††03, bits 0 to 3 (Speed Unit).

Yes

Yes

Yes

OW††12

Forward Speed Limit

1 = 0.01% (percentage of rated speed)

Yes

OW††13

Reverse Speed Limit

1 = 0.01% (percentage of rated speed)

Yes

OL††14

Positive Side Limiting Torque
Setting at Speed Reference

Unit is according to OW††03, bits 0 to 3 (Speed Unit).

Yes

Yes

(cont’d)

Register No.

Name

Description

SVB

-01

SVA

-01

SVR

Advertising