10 ) torque reference (trq), A ] operating procedure [ b ] related parameters – Yaskawa MP2200 Machine Controller User Manual

Page 451

Advertising
background image

8.3 Motion Commands

8-35

( 10 ) Torque Reference (TRQ)

The SVR does not support a torque control function.

[ a ] Operating Procedure

[ b ] Related Parameters

Setting Parameters

Monitoring Parameters

No.

Execution Conditions

Confirmation Method

1

There are no alarms.

Both IL††02 and IL††04 are 0.

2

Motion command execution has been completed.

IW††08 is 0 and IB††090 is OFF.

Execute the

TRQ motion command.

• Set OW††08 to 24.

The value 24 is returned to IW††08.

Execute another motion command to cancel the
torque control mode.

OW

08 = 24 (TRQ)

IW

08 = 24 (TRQ)

IB

090 (BUSY)

IB

098 (COMPLETE)

IB

0C0 (DEN)

IB

0C1 (POSCOMP)

IB

0C3 (NEAR)

Parameter

Name

Setting

OW††08

Motion Command

The mode is changed to torque control when this parameter is set to 24.

Parameter

Name

Monitor Contents

IW††08

Servo Command Type
Response

Indicates the motion command that is being executed.
The response code will be 24 during TRQ command execution.