10.1 Motion Errors

10-25

* Automatically reflected when the User Constants Self-Writing Function is enabled in the fixed

parameters and the setting for the S-curve Acceleration Time, Acceleration Time Constant, or
Deceleration Time Constant is changed at the same time that the move command is set.

24

Torque Reference
(TRQ)

Command was sent while connected through
MECHATROLINK-I.

No alarm or warning

Alarm occurred.

Communications are not synchronized.

“Servo Driver Synchronization Communication Error”
alarm

25

Phase Reference
(PHASE)

The axis is an absolute infinite length axis and the
Zero Point Return (Setting) has not been completed.

“Zero Point Not Set” alarm

Servo OFF status

“Servo OFF” alarm

Alarm occurred.

Communication is not synchronized.

“Servo Driver Synchronization Communication Error”
alarm

26

Change Position
Integration Time
Constant (KIS)

Alarm occurred.

Communication is not synchronized.

“Servo Driver Synchronization Communication Error”
alarm

A Servo parameter write operation was not completed
within the required time.

“Servo Driver Command Timeout Error” alarm

An A.94 or A.95 warning occurred in the Servo.

“Servo Driver Error” warning

Other Commands

• Automatically reflected in

parameter when move
command starts.

Alarm occurred.

Communication is not synchronized.

“Servo Driver Synchronization Communication Error”
alarm

A Servo parameter write operation was not completed
within the required time.

“Servo Driver Command Timeout Error” alarm

An A.94 or A.95 warning occurred in the Servo.

“Servo Driver Error” warning

Pulse distribution was not completed (DEN = OFF).

No alarm or warning

(cont’d)

Motion Command Code

Cause of Command Error End Status

Simultaneously Occurring Warnings or Alarms

Advertising