(cont’d)

Bit 6

POSMAX Preset

Presets the POSMAX Number of Turns (monitoring parameter IL††1E) to the value set for the Preset
Data of POSMAX Turn (setting parameter OL††4C).
0: POSMAX Preset OFF (default)
1: POSMAX Preset ON

Bit 7

Infinite Length Axis Position Information LOAD

When an infinite length axis is used with an absolute encoder, reset the position information with the
encoder position that existed when the power was OFF and the data set for the pulse position when the
power was OFF. When processing has been completed for this bit, the ABS System Infinite Length
Position Control Information LOAD Completed bit will be turned ON in the Position Management
Status (monitoring parameter IW††0C, bit 8).
0: Infinite Length Axis Position Information LOAD OFF (default)
1: Infinite Length Axis Position Information LOAD ON

Bit 8

Forward External Torque Limit Input

Limit the torque by the value set in the SERVOPACK parameters.
The setting is enabled when the move command or the SERVO ON command is sent.
There is no torque limit switch parameter in the Servo command option area in the SGD-N, SGDB-N,
or SGDH+NS100/NS115 SERVOPACKs, so the torque limit input cannot be used.
0: Forward External Torque Limit Input OFF (default)
1: Forward External Torque Limit Input ON

Bit 9

Reverse External Torque Limit Input

Limit the torque by the value set in the SERVOPACK parameters.
The setting is enabled when the move command or the SERVO ON command is sent.
There is no torque limit switch parameter in the Servo command option area in the SGD-N, SGDB-N,
or SGDH+NS100/NS115 SERVOPACKs, so the torque limit input cannot be used.
0: Reverse External Torque Limit Input OFF (default)
1: Reverse External Torque Limit Input ON

Bit B

Integration Reset

Reset the position loop integral items for the SERVOPACK.
The setting is enabled when the move command or the SERVO ON command is sent.
The Integration Reset (Position Loop Integration Reset) is supported only by the SGDS SERVOPACK
and cannot be used for other SERVOPACKs.
0: Integration Reset OFF (default)
1: Integration reset ON

Bit F

Clear Alarm

Clear alarms.
If a communication error occurs, communication can be reestablished by clearing the alarm.
0: Clear alarm OFF (default)
1: Clear alarm ON