5.2 Motion Command Details

5-75

( 3 ) Related Parameters

[ a ] Setting Parameters

[ b ] Monitoring Parameters

( 4 ) Timing Charts

[ a ] Normal End

[ b ] Error End

Parameter

Name

Setting

OW††03

Function 1

Set the speed unit, acceleration/deceleration unit, and filter type.

OW††08

Motion Command

The linear acceleration time constant is changed when this parameter is set to 10.

OB††090

Command Pause

This parameter is ignored for ACC command.

OB††091

Command Abort

This parameter is ignored for ACC command.

OL††36

Linear Acceleration
Time

Set the acceleration for feeding as the acceleration time.

Parameter

Name

Monitor Contents

IL††02

Warning

Stores the most current warning.

IL††04

Alarm

Stores the most current alarm.

IW††08

Servo Command
Type Response

Indicates the motion command that is being executed.
The response code will be 10 during ACC command execution.

IB††090

Command Executing

Turns ON during ACC command execution and turns OFF when execution has been
completed.

IB††091

Command Hold
Completed

Always OFF for ACC command.

IB††093

Command Error End

Turns ON if an error occurs during ACC command execution. Turns OFF when another
command is executed.

IB††098

Command Execution
Completed

Turns ON when ACC command execution has been completed.

OW

08 = 10 (ACC)

IW

08 = 10 (ACC)

IB

090 (BUSY)

Undefined length
of time

IB

098 (COMPLETE)

IB

093 (FAIL)

Undefined length
of time

OW

08 = 10 (ACC)

IW

08 = 10 (ACC)

IB

090 (BUSY)

IB

098 (COMPLETE)

IB

093 (FAIL)