3 ) related parameters, 4 ) timing charts – Yaskawa MP2200 Machine Controller User Manual

Page 303

Advertising
background image

5.2 Motion Command Details

5-73

( 3 ) Related Parameters

[ a ] Setting Parameters

[ b ] Monitoring Parameters

( 4 ) Timing Charts

Normal Execution

Parameter

Name

Setting

OW††08

Motion Command

Set to 9 for ZSET command.

OB††090

Command Pause

This parameter is ignored for ZSET command.

OB††091

Command Abort

This parameter is ignored for ZSET command.

OL††48

Zero Point Offset

Sets the offset from the zero point in the machine coordinate system after the zero point
has been set.

Parameter

Name

Monitor Contents

IL††02

Warning

Stores the most current warning.

IL††04

Alarm

Stores the most current alarm.

IW††08

Servo Command
Type Response

Indicates the motion command that is being executed.
The response code will be 9 during ZSET command execution.

IB††090

Command Executing

Turns ON during ZSET command execution and turns OFF when ZSET command
execution has been completed.

IB††091

Command Hold
Completed

Always OFF for ZSET command.

IB††093

Command Error End

Turns ON if an error occurs during ZSET command execution. Turns OFF when
another command is executed.

IB††098

Command Execution
Completed

Turns ON when ZSET command execution has been completed.

IB††0C5

Zero Point Return
(Setting) Completed

Turns ON when the zero point has been established.

OW

08 = 9 (ZSET)

IW

08 = 9 (ZSET)

IB

090 (BUSY)

IB

098 (COMPLETE)

IB

0C5 (ZRNC)

IB

093 (FAIL)