9.4 Parameters That Are Automatically Updated

9-19

9.4 Parameters That Are Automatically Updated

The function described in this section is supported by the SVB-01 Module. It cannot be used
with the SVA-01 Module.

9.4.1 Parameters Updated when a Connection Is Established

(MP2200/MP2300 to SERVOPACK)

* Only when bit A of fixed parameter 1 is set to enable automatic updating of parameters.

MP2200/MP2300

SERVOPACK

Remarks

SGD-N,

SGDB-N

NS100

NS115

SGDS

Fixed
Parameters

Backlash Compensation

No.16

Pn81B

Pn214

Setting
Parameters

Position Completed Width

*

OL††1E

Pn500

Pn522

For MECHATROLINK-II
at 10 Mbps in 32-byte mode
only

Position Loop Gain

*

OW††2E

Pn102

Speed Loop Gain

*

OW††2F

Pn100

Speed Feed Forward
Compensation

*

OW††30

Pn109

Position Loop Integration
Time Constant

*

OW††32

Pn11F

Speed Loop Integration Time
Constant

*

OW††34

Pn101

Linear Acceleration Time*

OL††36

Cn-0020

Pn80B

Linear Deceleration Time*

OL††38

Pn80E

S-curve Acceleration Time

*

OW††3A

Cn-0026

Pn812

Fixed
values

65535

Cn-001E

Excessive Following Error
Area

32767

Pn505

Overtravel Level

2

30 -1

Pn520

Excessive Following Error
Alarm Detection Level

100

Pn51E

Excessive Following Error
Warning Detection Level

Pn820 and Pn822 are set to
the same values.

Pn820

→Pn822

Processing to disable the
latch zone.