7 Absolute Position Detection

7.2.2 Setting Related Parameters

7-6

[ b ] Number of Encoder Pulses

• MP2200/MP2300 fixed parameter 36

Set MP2200/MP2300 fixed parameter 36 to the number of pulses used by the absolute encoder

as shown in the following table.

*

Set 16384 for the

Σ

-II.

If the above settings are not used, correct motion control will not be performed. Set the parameters
carefully.

[ c ] Axis Selection

• MP2200/MP2300 fixed parameter 1, bit 0

This setting is used to set either an infinite or finite length axis for controlled axis movement.
Refer to 7.3 Using an Absolute Encoder for position management methods for finite and
infinite length axes.

[ d ] Infinite Length Axis Reset Position

• MP2200/MP2300 fixed parameter 10

The Infinite Length Axis Reset Position is used to set the reset position of infinite length axis per
rotation in reference units. This parameter is enabled when an axis type is set to a infinite length axis.

[ e ] Maximum Number of Absolute Encoder Turns/Multiturn Limit Setting

• MP2200/MP2300 fixed parameter 38

Σ

-II and

Σ

-III Series SERVOPACK parameter Pn205

These parameters determine the maximum value of the number of encoder turns managed by the
SERVOPACK and MP2200/MP2300. The setting is determined by the SERVOPACK that is used

and the type of axis, as shown in the following table.

* A fixed parameter setting error will occur if fixed parameter 38 is set to 65535 for the

Σ-ΙΙ

Series with an infinite length axis.

If the above settings are not used, the position may be offset. Set the parameters carefully.

Number of

Bits

MP2200/MP2300

Fixed Parameter 36

SERVOPACK Parameter

Σ Series
Cn-0011

Σ-II Series

Pn201

Σ-III Series

Pn212

12

4096

1024

1024

1024

13

8192

2048

2048

2048

14

16384 4096

4096

4096

15

32768

8192

8192

8192

16

65536

16384 16384

17

131092 *

16384

32768

IMPORTANT

Fixed Parameter 38

SERVOPACK Parameter

Pn205

Finite length axis for

Σ Series

99999

Infinite length axis for

Σ Series

99999

Finite length axis for

Σ-II or Σ-III Series

65535

65535

Infinite length axis for

Σ-II or Σ-III Series

Set to the same value as Pn205*

65534 max.*

IMPORTANT