7.3 Using an Absolute Encoder

7-29

Use the following flowchart to set up position data again.

Toggle Buffer Selection Flag ON?

Copy buffer 0 to setting parameters.

Start the high-speed scan drawing.

End the high-speed scan drawing.

NO

YES

YES

YES

YES

YES

NO

NO

NO

NO

Toggle Buffer Enabled Flag ON?

First scan after the start of high-speed
scan or signal indicating that the servo
power supply was turned back ON?

Position Data Re-setup
Request Flag ON

Position Data Re-setup
Request Flag OFF

Motion Controller RUN Ready and
Position Data Re-setup Request Flag ON?

Absolute System Infinite Length Position
Control Information Load Request Flag
OFF?

Copy buffer 1 to setting parameters.

Absolute system Position Control
Data Initialization Request Flag ON

Absolute System Infinite Length
Position Control Data Initialization
Request Flag OFF

Position Data Storage Request Flag
ON

Position Data Re-setup Request Flag
OFF