7 Absolute Position Detection

7.2.2 Setting Related Parameters

7-4

7.2.2 Setting Related Parameters

This section explains absolute position detection parameters in the MP2200/MP2300 parameters.
Set the following MP2200/MP2300 parameters and SERVOPACK parameters prior to startup the
absolute position detection system.

( 1 ) MP2200/MP2300 Parameters

( 2 ) SERVOPACK Parameters

• The parameters for which IMPORTANT precautions are provided must be set. If they are not set correctly,

the current position after turning ON the power supply may not be correct.
Machine damage may occur. Set these parameters carefully.

CAUTION

Table 7.1 MP2200/MP2300 Parameters

Parameter No.

Name

Setting Range

Units

Fixed Parameter 1, bit 0

Axis Type

0: Finite length axis, 1: Infinite length axis

Fixed Parameter 1, bit 9

Simple ABS Infinite Axis

0: Disable, 1: Enable

Fixed Parameter 10

Maximum Value of Rotary
Counter

1 to 2

31

−1

1 = 1 reference
unit

Fixed Parameter 30

Encoder Type

• Incremental encoder
• Absolute encoder
• Absolute encoder

(used as incremental encoder)

Fixed Parameter 36

Encoder Resolution

1 to 2

31

−1

Set the value after multiplication. (For a 16-bit
encoder, set 2

16

= 65536.)

pulse

Fixed Parameter 38

Max. Revolutions of
Absolute Encoder

0 to 2

31

−1

1 = 1 rotation

SERVOPACK

Model

Parameter

Name

Setting Range

Units

Σ Series

*

Cn-0001, bit E

Encoder Selection

0: Incremental encoder
1: Absolute encoder

Cn-0002, bit 0

Rotation Direction
Selection

0: Sets counterclockwise (CCW) rotation as forward

rotation.

1: Sets clockwise (CW) rotation as forward rotation

(reverse rotation mode).

Cn-0011

Number of Encoder Pulses

513 to 32767

P/R

Σ-II Series

*

Pn000.0

Direction Selection

0: Sets counterclockwise (CCW) rotation as forward

direction.

1: Sets clockwise (CW) rotation as forward direction

(reverse rotation mode).

Pn205

Multiturn Limit Setting

0 to 65535

Rev

Pn002.2

Absolute Encoder Usage

0: Uses absolute encoder as an absolute encoder.
1: Uses absolute encoder as an incremental encoder.