Yaskawa MP2200 Machine Controller User Manual

Page 83

Advertising
background image

3.1 SVB-01 Module Setup

3-11

SVB-01 Module to SERVOPACK

(Note)1. The default settings are written if the axis is not set.

2. When the axis has been set, parameters are written only when bit 10 of fixed

parameter 1 is set to enable automatic updating of parameters.

3. The positioning completed width is written only when MECHATROLINK-II

(32-byte mode) is used.

4. The above parameters are written to the SERVOPACK’s RAM.

[ c ] SERVOPACK Parameters

The SERVOPACK parameters are automatically set, as shown below.
These settings, however, are not written to the set values for the SERVOPACK parameters saved in
the SVB-01 Module.
The MPE720 is required to change SERVOPACK parameters in the SVB-01 Module. For details,
refer to ( 4 ) SVB Definitions of 3.1.3 Module Configuration Definitions.

(Note)1. The above processing is not performed when the axis has been set.

2. The above set values are written to the SERVOPACK’s EEPROM.

SVB-01 Module

SERVOPACK

Setting Parameters

SGD-N, SGDB-

N

SGDH+

NS100

SGDH+

NS115

SGDS

Address

Name

OL††1E

Positioning Completed Width

Pn500

Pn522

OL††36

Linear Acceleration Time

Cn-0020

Pn80B

OL††38

Linear Deceleration Time

Pn80E

SVB-01 Module

SERVOPACK

SERVOPACK Parameters

SGD-N,

SGDB-N

SGDH+

NS100

SGDH+

NS115

SGDS

Name

Set Value

P-OT Signal Mapping

Not valid.

Cn-0001

Bit 2

Pn50A.3

N-OT Signal Mapping

Not valid.

Cn-0001

Bit 3

Pn50B.0

SERVOPACK Software Limit
Function (Positive)

Not valid.

Cn-0014

Bit 2

Pn801.0

SERVOPACK Software Limit
Function (Negative)

Not valid.

Cn-0014

Bit 3

SERVOPACK Electronic Gear
Ratio (Numerator)

1

Cn-0024

Pn202

Pn20E

SERVOPACK Electronic Gear
Ratio (Denominator)

1

Cn-0025

Pn203

Pn210

Autotuning Application Switch

Not valid.

Pn110

/DEC Signal Mapping

CN1-9 input

terminal

Pn511.0

/EXT1 Signal Mapping

CN1-10 input

terminal

Pn511.1

/EXT2 Signal Mapping

CN1-11 input

terminal

Pn511.2

/EXT3 Signal Mapping

CN1-12 input

terminal

Pn511.3

Speed Reference Command
Options

Use T-REF as

external torque

limit value.

Pn002.0

Torque Reference Command
Options

Use V-REF as
external speed

limit input.

Pn002.1

Advertising