8 SVR Virtual Motion Module

8.3.2 Motion Command Details

8-24

[ b ] Related Parameters

Setting Parameters

Monitoring Parameters

Parameter

Name

Setting

OB††000

Servo ON

Turn the power to the Servomotor ON and OFF.
1: Power ON to Servomotor, 0: Power OFF to Servomotor
Turn ON the power before setting the Motion Command Code (OW††08) to 3.

OW††03

Function 1

Set the speed unit, acceleration/deceleration unit, and filter type.

OW††08

Motion Command

The zero point return operation starts when this parameter is set to 3. The operation will
be canceled if this parameter is set to 0 during ZRET command execution.

OB††091

Command Abort

The zero point return operation will be canceled if this bit is set to 1 during zero point
return operation.

OB††095

Position Reference
Type

Switch the type of position reference.
0: Incremental addition mode, 1: Absolute mode
Set this parameter before setting the Motion Command Code (OW††08) to 3.

OW††3D

Home Window

Set the width in which the Zero Point Position bit (IB††0C4) will turn ON.

Parameter

Name

Monitor Contents

IB††001

Servo ON

Indicates the Servo ON status.
ON: Power supplied to Servomotor, OFF: Power not supplied to Servomotor

IL††02

Warning

Stores the most current warning.

IL††04

Alarm

Stores the most current alarm.

IW††08

Servo Command
Type Response

Indicates the motion command that is being executed.
The response code will be 3 during ZRET command execution.

IB††090

Command Executing

Turns ON during zero point return operation. Turns OFF when ZRET command
execution has been completed.

IB††091

Command Hold
Completed

Always OFF for ZRET command.

IB††093

Command Error End

Turns ON if an error occurs during ZRET command execution. Turns OFF when
another command is executed.

IB††098

Command Execution
Completed

Turns ON when ZRET command execution has been completed.

IB††0C0

Distribution
Completed

Turns OFF for 1 scan.

IB††0C3

Position Proximity

Turns OFF for 1 scan.

IB††0C4

Zero Point Position

Turns ON if the current position after the zero point return operation has been
completed is within the Zero Point Position Output Wide from the zero point position.
Turns OFF is the current position is not within this width.

IB††0C5

Zero Point Return
Completed

Turns ON when the zero point return has been completed.