11 ) reference monitor – Yaskawa MP2200 Machine Controller User Manual

Page 173

Advertising
background image

4.3 SVB-01 Module Parameter Details

4-53

( 11 ) Reference Monitor

IL††1A

Position Error (PERR)

Range

Unit

−2

31

to 2

31

−1

Reference unit

Stores the following error (Machine Coordinate System Position (IL††12) – Machine Coordinate Feedback Position
(IL††16)) managed by the Motion Module.

IL††1C

Target Position Difference Monitor

Range

Unit

−2

31

to 2

31

−1

Reference unit

Stores the number of pulses distributed each scan.

IW††1E

POSMAX Number of Turns

Range

Unit

−2

31

to 2

31

−1

rev

This parameter is valid for an infinite length axis.
The count stored in this parameter goes up and down every time the current position exceeds the Maximum Value of Rotary
Counter (POSMAX) (fixed parameter 10).

1

Machine Coordinate System

The basic coordinate system that is set according to Zero Point Return (ZRET) command execution or Zero Point Setting
(ZSET) command execution. The MP2200/MP2300 manages the positions using this machine coordinate system.

(cont’d)

TERMS

IL††20

Speed Reference Output Monitor

Range

Unit

−32768 to 32767

(

−2

31

to 2

31

−1)

pulse/s

Stores the speed reference that is being output.
This parameter monitors the speed being output to the MECHATROLINK. This parameter will be 0 for interpolation or phase
control.