4.3 SVB-01 Module Parameter Details

4-21

( 7 ) Backlash Compensation

( 8 ) SERVOPACK Settings

No. 16

Backlash Compensation

Setting Range

Setting Unit

Default Value

−2

31

to 2

31

−1

Reference unit

0

Set the backlash compensation in reference units.
Backlash compensation can be disabled by setting this parameter to 0.
Perform backlash compensation using the functions at the SERVOPACK. The setting is enabled when communication is
established with the SERVOPACK (NS115: Pn81B, SGDS: Pn214).
Backlash compensation cannot be used for the SERVOPACK SGD-N, SGDB-N, or SGDH + NS100 because they do not have a
parameter to set the backlash compensation.

• Using Backlash Compensation in Forward Direction

• Using Backlash Compensation in Reverse Direction

Compensation

Machine

Machine

Motor axis

Motor axis

Travels
opposite of
Home Direction.

Reference
position

Reference
position

Backlash Compensation
in fixed parameter 16

Home Direction

Compensation

Compensation

Machine

Motor axis

Motor axis

Reverse direction

Machine

No. 29

Motor Type

Setting Range

Setting Unit

Default Value

0 or 1

0

Set the type of motor that is used.
An alarm (IL††04, bit 30) will occur if this setting does not match with the type of motor actually used.

0: Rotary motor (default)
1: Linear motor

No. 30

Encoder Type

Setting Range

Setting Unit

Default Value

0 to 3

0