7 ) acceleration/deceleration filter settings – Yaskawa MP2200 Machine Controller User Manual

Page 230

Advertising
background image

4 Motion Parameters

4-110

( 7 ) Acceleration/Deceleration Filter Settings

There are two types of acceleration/deceleration filter: The exponential acceleration/deceleration
filter and the moving average filter. The parameters related to the acceleration/deceleration filter
settings are listed in the following table. When using an acceleration/deceleration filter, always
execute the Change Filter Type command (OW††08 = 13) in advance to enable the filter type
selection.

Parameter Type

Parameter No.

(Register No.)

Name

Description

Default

Value

Motion Setting
Parameters

OW††03
Bits 8 to B

Filter Type

Set the acceleration/deceleration filter type.

0: No filter
1: Exponential acceleration/deceleration filter
2: Moving average filter

Note:
The Change Filter Type command (OW††08 = 13) must be
executed in advance to enable the Filter Type.

0

OW††3A

S-curve

Acceleration Time

Set the acceleration/deceleration filter time constant.
Always make sure that pulse distribution has been completed (i.e.,
that monitoring parameter IW††0C, bit 0 is ON (1)) before
changing the time constant.

0

Advertising