Yaskawa MP2200 Machine Controller User Manual

Page 438

Advertising
background image

8 SVR Virtual Motion Module

8.3.2 Motion Command Details

8-22

[ b ] Related Parameters

Setting Parameters

Monitoring Parameters

Parameter

Name

Setting

OB††000

Servo ON

Turn the power to the Servomotor ON and OFF.
1: Power ON to Servomotor, 0: Power OFF to Servomotor
Turn ON the power before setting the Motion Command (OW††08) to 2.

OW††03

Function 1

Set the speed unit, acceleration/deceleration unit, and filter type.

OW††08

Motion Command

The positioning starts when this parameter is set to 2. The operation will be canceled if this
parameter is set to 0 during EX_POSING command execution.

OB††090

Command Pause

The axis will decelerate to a stop if this bit is set to 1 during execution of EX_POSING
command execution. The positioning will restart if this bit is turned OFF when a command is
being held.

OB††091

Command Abort

The axis will decelerate to a stop if this bit is set to 1 during EX_POSING command execution.

OB††095

Position Reference
Type

Switch the type of position reference.
0: Incremental addition mode, 1: Absolute mode
Set this parameter before setting the Motion Command (OW††08) to 2.

OL††10

Speed Reference

Specify the speed for the positioning. This setting can be changed during operation. The unit
depends on the setting of OW††03.

OL††1C

Position Reference
Setting

Set the target position for positioning. This setting can be changed during operation. The
meaning of the setting depends on the status of OB††095.

OL††36

Linear Acceleration
Time

Set the rate of acceleration or acceleration time constant for positioning.

OL††38

Linear Deceleration
Time

Set the rate of deceleration or deceleration time constant for positioning.

OW††3A

S-Curve Acceleration
Time

Set the acceleration/deceleration filter time constant. Exponential acceleration/deceleration or a
moving average filter can be selected in OW††03.
Change the setting only after pulse distribution has been completed for the command
(IB††0C0 is ON).

Parameter

Name

Monitor Contents

IB††001

Servo ON

Indicates the Servo ON status.
ON: Power supplied to Servomotor, OFF: Power not supplied to Servomotor

IL††02

Warning

Stores the most current warning.

IL††04

Alarm

Stores the most current alarm.

IW††08

Servo Command Type
Response

Indicates the motion command that is being executed.
The response code is 2 during EX_POSING command execution.

IB††090

Command Executing

The Command Executing bit will turn ON during EX_POSING command execution and then
turn OFF when command execution has been completed.

IB††091

Command Hold
Completed

Turns ON when a deceleration to a stop has been completed as the result of setting the
Command Pause bit (OB††090) to 1 during EX_POSING command execution.

IB††093

Command Error End

Turns ON if an error occurs during EX_POSING command execution. The axis will
decelerate to a stop if it is moving. Turns OFF when another command is executed.

IB††098

Command Execution
Completed

Turns ON when EX_POSING command execution has been completed.

IB††0C0

Distribution Completed Turns ON when pulse distribution has been completed for the move command.

Turns OFF during execution of a move command.

IB††0C1

Positioning Completed Turns ON when pulse distribution has been completed and the current position is within the

Positioning Completed Width. OFF in all other cases.

IB††0C3

Position Proximity

Turns ON when Distribution Completed (DEN) turns ON.

Advertising