5.2 Motion Command Details

5-43

Detecting the OT Signal during Approach Speed Movement

* 1. SVB-01: SERVOPACK EXT1 signal, SVA-01: DI_2 signal
* 2. The SERVOPACK P-OT signal.
* 3. The SERVOPACK N-OT signal.

Note)The stopping method when the OT signal is detected depends on the setting of

SERVOPACK parameters.

HOME signal

*1

NOT

*3

POT

*2

Start

Zero Point

Creep Speed

(OL

40)

Home Offset

(OL

42)

Positioning Speed

(OL

10)

Phase-C pulse

Approach Speed

(OL

3E)

HOME signal

*1

NOT

*3

POT

*2

Start

Zero Point

Creep Speed

(OL

40)

Home Offset

(OLxx42)

Positioning Speed

(OL

10)

Phase-C pulse

Approach Speed

(OL

3E)

Approach Speed

(OL

3E)

Parameter

Name

Setting

OW††3C

Home Return Type

14: Home LS & C pulse Method

OL††10

Speed Reference

Set the positioning speed to use after detecting the phase-C pulse. The sign is ignored. The
travel direction depends on the sign of the Home Offset.

OL††18

Speed Override

This parameter allows the Zero Point Return speed to be changed without changing
the Speed Reference (OL††10). Set the override value as a percentage of the
Speed Reference. This setting can be changed during operation.
Setting range: 0 to 32767 (0% to 327.67%);
Setting unit: 1 = 0.01%

OL††3E

Approach Speed

Set the speed to use when starting a zero point return. The travel direction will depend on the
sign of the approach speed.

OL††40

Creep Speed

Set the speed to use after detecting the home signal. The travel direction will depend on the
sign of the creep speed.

OL††42

Home Offset

Set the travel distance from the point where a phase-C pulse is detected. The travel direction
will depend on the sign.