5 Motion Commands

5.2.11 Change Filter Time Constant (SCC)

5-78

5.2.11 Change Filter Time Constant (SCC)

The SCC command transfers the setting of the S-Curve Acceleration Time (motion setting parameter
OW††3A) to the Moving Average Time in the SERVOPACK and enables the setting.
Always execute the CHG_FILTER command before executing SCC command.

( 1 ) Operating Procedure

( 2 ) Holding and Aborting

The Command Pause bit (OB††090) and the Command Abort bit (OB††091) cannot be used.

No.

Execution Conditions

Confirmation Method

1

There are no alarms.

Both IL††02 and IL††04 are 0.

2

The Servo ON condition.

IB††001 is ON.

3

Pulse distribution has been completed for the
SERVOPACK.

IB††0C0 is ON.

4

Motion command execution has been completed.

IW††08 is 0 and IB††090 is OFF.

Execute the SCC motion command.

• Set OW††08 to 12.

• With the MECHATROLINK-II, there is the function that the change of

setting parameter is automatically updated. If utilizing this function ,
there is no need to execute SCC command. For details, refer to bit A
(User Constants Self-writing Function) in Fixed Parameter 1 (Function
Selection 1).

• The Command Pause (OB††090) cannot be used.
• The Command Abort (OB††091) cannot be used.

Filter Time Constant is set in the SERVOPACK
and enabled.

• IW††08 will be 12 during command

execution.

• IB††090 will be ON during command

execution.

Parameter change completed.

• IW††08 will be 12 and IB††090 will be

OFF.

Execute NOP motion command.

• Set OW††08 to 0.