5.2 Motion Command Details

5-77

( 3 ) Related Parameters

[ a ] Setting Parameters

[ b ] Monitoring Parameters

( 4 ) Timing Charts

[ a ] Normal End

[ b ] Error End

Parameter

Name

Setting

OW††03

Function 1

Set the speed unit, acceleration/deceleration unit, and filter type.

OW††08

Motion Command

The linear deceleration time constant is changed when this parameter is set to 11.

OB††090

Command Pause

This parameter is ignored for DCC command.

OB††091

Command Abort

This parameter is ignored for DCC command.

OL††38

Linear Deceleration
Time

Set the deceleration for feeding as the deceleration time.

Parameter

Name

Monitor Contents

IL††02

Warning

Stores the most current warning.

IL††04

Alarm

Stores the most current alarm.

IW††08

Servo Command
Type Response

Indicates the motion command that is being executed.
The response code will be 11 during DCC command execution.

IB††090

Command Executing

Turns ON during DCC command execution and turns OFF when execution has been
completed.

IB††091

Command Hold
Completed

Always OFF for DCC command.

IB††093

Command Error End

Turns ON if an error occurs during DCC command execution. Turns OFF when another
command is executed.

IB††098

Command Execution
Completed

Turns ON when DCC command execution has been completed.

OW

08 = 11 (DCC)

IW

08 = 11 (DCC)

IB

090 (BUSY)

Undefined length
of time

IB

098 (COMPLETE)

IB

093 (FAIL)

OW

08 = 11 (DCC)

IW

08 = 11 (DCC)

IB

090 (BUSY)

IB

098 (COMPLETE)

IB

093 (FAIL)

Undefined length
of time