8 SVR Virtual Motion Module

8.3.2 Motion Command Details

8-38

( 12 ) Other Commands

Other commands do not have functions for the SVR. The Motion Command (OW††08) is returned
to the Motion Command Response Code (IW††08).

[ a ] Operating Procedure

ALM_MON, ALM_HIST, or ALMHIST_CLR

Other Commands

* Motion Command Codes for Each Command

[ b ] Related Parameters

Setting Parameters

Monitoring Parameters

No.

Execution Conditions

Confirmation Method

1

Motion command execution must be completed.

IW††08 must be 0 and IB††090 must be OFF.

No.

Execution Conditions

Confirmation Method

1

There must be no alarms.

Both IL††02 and IL††04 must be 0.

2

Motion command execution must be completed.

IW††08 must be 0 and IB††090 must be OFF.

Execute cmd motion command.

• Set OW††08 to code.

The code is returned to IW††08.

Execute another motion command to cancel the
current command.

OW

08="code"

IW

08="code"

IB

090(BUSY)

IB

098(COMPLETE)

IB

0C0(DEN)

IB

0C1(PSET)

IB

0C3(NEAR)

Command (cmd)

Code (code)

Command (cmd)

Code (code)

Command (cmd)

Code (code)

ACC

10

KPS

15

ALM_HIST

20

DCC

11

KFS

16

ALMHIST_CLR

21

SCC

12

PRM_RD

17

KIS

26

CHG_FILTER

13

PRM_WR

18

KVS

14

ALM_MON

19

Parameter

Name

Setting

OW††08

Motion Command

Executes a command when the command code is set.

Parameter

Name

Monitor Contents

IW††08

Motion Command
Type Response

Indicates the motion command that is being executed.