5 Motion Commands

5.2.19 Monitor SERVOPACK Alarm History (ALM_HIST)

5-94

5.2.19 Monitor SERVOPACK Alarm History (ALM_HIST)

The ALM_HIST command reads the alarm history that is stored in the SERVOPACK and stores it in
Servo Alarm Code (monitoring parameter IW††2D).

( 1 ) Operating Procedure

( 2 ) Holding and Aborting

The Command Pause bit (OB††090) and the Command Abort bit (OB††091) cannot be used.

( 3 ) Related Parameters

[ a ] Setting Parameters

No.

Execution Conditions

Confirmation Method

1

Motion command execution has been completed.

IW††08 is 0 and IB††090 is OFF.

Execute the

ALM_HIST motion command.

• Set OW††08 to 20.

• The Command Pause (OB††090) cannot be used.
• The Command Abort (OB††091) cannot be used.

The alarm history stored in the SERVOPACK is
read and the codes are stored in the monitoring
parameters.

• IW††08 will be 20 during command

execution.

• IB††090 will be ON during command

execution.

Execution completed.

• IW††08 will be 20 and IB††090 will be

OFF.

Execute NOP motion command.

• Set OW††08 to 0.

Parameter

Name

Setting

OW††08

Motion Command

The alarm history is monitored when this parameter is set to 20.

OB††090

Command Pause

This parameter is ignored for ALM_HIST command.

OB††091

Command Abort

This parameter is ignored for ALM_HIST command.

OW††4F

Servo Alarm Monitor
Number

Set the number of the alarm to be monitored.