10.1 Motion Errors

10-21

( 2 ) Motion Program Alarm List

The motion program alarm codes are listed in the following tables. When displaying these on the
register list, set the display mode to hexadecimal (H).

* The axis number is stored in bits 8 to 11 for axis alarms.

Alarm Code

Description

Correction

P

rog

ra

m

al

a

rm

s

0

No alarm

Check the specifications for the instruction
that was being executed in the motion
program when the alarm occurred
according to the meaning of the alarm code.

10h

Complete circle specified for radius designation

11h

Interpolation feed speed exceeded

12h

Interpolation feed speed not specified

13h

Range exceeded after acceleration/deceleration speed
parameter conversion

14h

LONG_MAX exceeded for circular arc length

15h

No vertical specification for circular plane designation

16h

No horizontal specification for circular plane designation

17h

Specified axes exceeded

18h

Number of turns exceeded

19h

LONG_MAX exceeded for radius

1Bh

Emergency stop in progress

1Ch

LONG_MAX exceeded for linear interpolation block moving
amount

1Dh

FMX not defined

1Eh

Address T out of range

1Fh

Address P out of range

20h

REG data error

21h

Function work duplication (Function work in second PFORK
column was used at a different nesting level.)

22h

Indirect register designation range error

23h

Reference unit conversion overflow

Axis al

arms

*

80h

Logical axis used prohibited

Check the specifications for the instruction
that was being executed in the motion
program when the alarm occurred
according to the meaning of the alarm code.

81h

Specifications exceeding POSMAX made for infinite length
axis designation

82h

LONG_MAX exceeded for axis moving distance

84h

Motion command duplication

85h

Motion command response duplication

87h

VEL setting data out of range

88h

INP setting data out of range

89h

ACC/SCC/DCC setting data out of range

8Ah

T reference for MVT instruction is 0

8Bh

Instruction designated that cannot be executed for the Motion
Module model

8Ch

Prohibition command executed when pulse distribution was
not completed

8Dh

Motion command error end status