4 Motion Parameters

4.3.2 Motion Setting Parameter Details

4-44

( 31 ) Supplemental Settings

( 32 ) Absolute Infinite Length Axis Position Control Information

( 33 ) Transparent Command Mode

1

Store:

The use of "store" here refers to information that is automatically transferred by the CPU system
without any action by the user. This term is mainly used with this meaning when explaining motion
monitoring parameters.

OW††5C

Fixed Parameter Number

Setting Range

Setting Unit

Default Value

0 to 65535

0

Set the number of the fixed parameter to read with the FIXPRM_RD motion subcommand.
The results of reading the fixed parameter will be stored

1

in the Fixed Parameter Monitor (monitoring parameter IL††56).

Position

Phase

Speed

Torque

OL††5E

Absolute Position at Power
OFF (Low Value)

Setting Range

Setting Unit

Default Value

−2

31

to 2

31

−1

pulse

0

This information is for infinite length axis position control when an absolute encoder is used.
The encoder position is stored in 4 words.
If the Infinite Length Axis Position Information LOAD bit is set to 1 in the RUN Commands (setting parameter OW††00, bit
7), the position information will be recalculated with the values set here and the Modularized Position at Power OFF (OL††62
and OL††64).

OL††60

Absolute Position at Power
OFF (High Value)

Setting Range

Setting Unit

Default Value

−2

31

to 2

31

−1

pulse

0

Same as for OL††5E.

OL††62

Modularized Position at Power
OFF (Low Value)

Setting Range

Setting Unit

Default Value

−2

31

to 2

31

−1

pulse

0

This information is for infinite length axis position control when an absolute encoder is used.
The axis position in pulses managed internally by the controller is stored in 4 words.
If the Infinite Length Axis Position Information LOAD bit is set to ON in the RUN Commands (setting parameter OW††00, bit
7), the position information will be recalculated with the values set here and the Absolute Position at Power OFF (OL††5E and
OL††60).

OL††64

Modularized Position at Power
OFF (High Value)

Setting Range

Setting Unit

Default Value

−2

31

to 2

31

−1

pulse

0

Same as for OL††62.

Position

Phase

Speed

Torque

Position

Phase

Speed

Torque

Position

Phase

Speed

Torque

Position

Phase

Speed

Torque

OW††70 to

OW††7E

Command Buffer for
Transparent Command Mode

Setting Range

Setting Unit

Default Value

0

This area is used for command data when MECHATROLINK servo commands are specified directly.

• MECHATROLINK-I and MECHATROLINK-II, 17-byte Mode: Data area = OW††70 to OW††77
• MECHATROLINK-II, 32-byte Mode: Data area = OW††70 to OW††7E

Position

Phase

Speed

Torque

TERMS