( 1 ) Motion Parameters for Torque Control

[ a ] Fixed Parameters

No.

Name

Setting Unit

Default Value

Setting Range

0

Run Mode

1

0 to 5

1

Function Selection 1

0000h

Bit setting

2

Function Selection 2

0000h

Bit setting

4

Command Unit

0

0 to 3

5

Number of Decimal Places

3

0 to 5

6

Command Unit per Revolution

Reference unit

10000

1 to 2

31

−1

8

Gear Ratio (Motor)

1

1 to 65535

9

Gear Ratio (Load)

1

1 to 65535

10

Maximum Value of Rotary Counter (POSMAX)

Reference unit

360000

1 to 2

31

−1

12

Forward Software Limit

Reference unit

2

31

−1

−2

31

to 2

31

−1

14

Reverse Software Limit

Reference unit

−2

31

−2

31

to 2

31

−1

16

Backlash Compensation

Reference unit

0

−2

31

to 2

31

−1

29

Motor Type

0

0, 1

30

Encoder Type

0

0 to 3

34

Rated Speed

min

−1

3000

1 to 32000

36

Encoder Resolution

pulse

65536

1 to 2

31

−1

38

Max. Revolution of Absolute Encoder

Rev

65534

0 to 2

31

−1

42

Feedback Speed Moving Average Time Constant

ms

10

0 to 32

Advertising