3 ) motion monitoring parameters – Yaskawa MP2200 Machine Controller User Manual

Page 430

Advertising
background image

8 SVR Virtual Motion Module

8.2.2 Motion Parameter Settings

8-14

( 3 ) Motion Monitoring Parameters

[ a ] Drive Status

[ b ] Over Range Parameter Number

[ c ] Warning

[ d ] Alarm

[ e ] Motion Command Response Code

IW††00

Drive Status

Range Unit

IW††00

Bit 0

Motion Controller Operation Ready

Turns ON when the Run Mode (fixed parameter 0) is set to 0 (Normal Running).
OFF: Operation not ready, ON: Operation ready

Bit 1

Running (Servo ON)

OFF: Stopped, ON: Running (Servo ON)

IW††01

Over Range Parameter Number

Range

Unit

0 to 65535

Stores the number of a parameter set outside the Range .

• Setting parameters: 0 to 999
• Fixed parameters: 1000 or higher

IL††02

Warning

Range

Unit

IL††02

Bit 1

Setting Parameter Error

OFF: In Range , ON: Outside Range

Bit 2

Fixed Parameter Error

OFF: In Range , ON: Outside Range

Bit 4

Motion Command Setting Error

OFF: Command setting normal, ON: Command setting error

IL††04

Alarm

Range

Unit

IL††04

Bit 5

Servo OFF

OFF: Servo ON, ON: Servo OFF

IW††08

Servo Command Type Response

Range

Unit

0 to 65535

Stores the motion command code for the command that is being executed.