5 Motion Commands

5.2.3 Zero Point Return (ZRET)

5-34

Related Parameters

Parameter

Name

Setting Contents

OW††3C

Home Return Type

7: DEC1 + LMT + Phase-C Pulse Method

OL††10

Speed Reference

Sets the speed to use when starting a zero point return.
Only a positive value can be set.
An error will occur if a negative value is set.

OL††3E

Approach Speed

Sets the approach speed shown in the preceding diagram.
Only a positive value can be set.
An error will occur if a negative value is set.

OL††40

Creep Speed

Sets the creep speed shown in the preceding diagram.
Only a positive value can be set.
An error will occur if a negative value is set.

OL††42

Home Offset

Sets the home offset distance shown in the preceding diagram.
If the sign is positive, travel will be in the same direction as the zero
point return direction.
if the sign is negative, travel will be in the direction opposite of the zero
point return direction.

Fixed parameter 1, bit

5

Deceleration Limit Switch
Inversion

It is possible to set whether or not to invert the polarity of the DI_5
signal, which is used for DEC1. (The status of OW††05, bit 8 cannot
be inverted.)
0: Do not invert.
1: Invert.

Fixed parameter 21,

bit 0

Deceleration Limit Switch
Signal

It is possible to select the signal to use for DEC1.
0: Use setting parameter OW††05, bit 8.
1: Use the DI_5 signal.

OW††05, bit 8

Deceleration Limit Switch
Signal for Zero Point
Return (DEC1)

When fixed parameter 21, bit 0 is set to 0, the DEC1 signal is input from
the ladder program.
0: OFF
1: ON

OW††03, bits 0 to 3 Speed Units

Sets the units for the Speed Reference (OL††10), Approach Speed
(OL††3E), and Creep Speed (OL††40).
0: Reference unit/s
1: 10

n

reference unit/min.

2: 0.01%
3: 0.0001%

OL††18

Speed Override

This parameter allows the Zero Point Return speed to be changed
without changing the Speed Reference (OL††10). This setting can be
changed during operation.
This parameter has no effect on the Approach Speed (OL††3E) or
Creep Speed (OL††40).
Setting range: 0 to 32768 (0% to 327.67%)
Setting units: 1 = 0.01%
Example: Setting for 50% = 5000