1.2 SVB-01 Module Overview and Features

1-7

1.2.6 Synchronization between Modules

( 1 ) Overview

Synchronization between the CPU and the Optional Modules is provided using hardware for the
MP2200/MP2300.
This enables synchronization between the high-speed scan and MECHATROLINK communication,
resulting in synchronization between SVB Modules built into the CPU Unit and SVB-01 Modules, as
well as between different SVB-01 Modules.
Synchronization between Modules was not possible with SVB-01 Modules of the MP920 and SVB
Modules of the CP9200SH.

When synchronized mode is used, the start of the high-speed scan and the various communication
cycles are synchronized. This means that commands from the high-speed scan will be sent at
consistent points in communication cycle processing and simplifies distribution processing for
interpolation commands.

JEPMC-AN2910

D/A Module
Analog outputs, -10 to 10 V, 2 channels

Yes

Yes

JAPMC-MC2310

SVB-01 Motion Module

Yes

Yes

JEVSA-YV250

MYVIS YV250 Machine Vision System

Yes

Yes

JEPMC-MC400

MP940 Machine Controller

Yes

No

(cont’d)

Model Number

Details

MECHATROLINK-I

MECHATROLINK-II

gh-speed scan

4 ms

2 ms

1 ms

2 ms

mmunication

cle for SVB built

o the CPU

mmunication

cle for SVB-01

mmunication

cle for SVB-01