7.3 Using an Absolute Encoder

7-17

„ The following methods are used to save the Zero Point Offset (OL††48).

Method 1: Saving in a M Register with Ladder Program
Subtract the Calculated Position in Machine Coordinate System from the Machine Coordinate System Zero
Point Offset and save the result in an M register when it is stored in setting parameter OL††48.
Store the contents saved in the M register in Zero Point Offset (setting parameter OL††48) when system
or servo power is turned back ON.
Ladder Program Example Required for a Finite Length Axis (Axis 1)

Method 2: Saving the Zero Point Offset (OL††48) from the MPE720 Parameter Window
After the Zero Point Offset (OL††48) is set after setting the zero point, use

Save

to save the settings to

the MP2300. When power is turned back ON, the value that was saved for Zero Point Offset (OL††48)
will be stored automatically.

INFO

Rising edge of Zero Point Set signal detected.

IB00106

DB000000

DB000001

0000

0000

NL-1

IF

DB000001==true

0001

0003

NL-1

Zero Point Offset

− Calculated Position Store in OL

48.

EXPRESSION

OL8048=OL8048-IL8010;

ML00400=OL8048;

0002

0004

NL-2

END_IF

0003

0005

NL-1

Store offset saved in M register in OL

48.

STORE

Source ML00400

Dest

OL8048

0004

0006

NL-1

END

0005

0007

NL-1

P00001 H09 Main Program