4.4 SVA-01 Module Parameter Details

4-91

( 6 ) Motion Command Status

( 7 ) Motion Subcommand Response Code

IW††09

Motion Command Status

Range

Unit

IW††09

Bit 0

Command Executing (BUSY) Flag

This bit indicates the motion command's execution status. Refer to Chapter 5 Motion Commands for
details on command timing charts.
OFF: READY (completed)
ON: BUSY (processing)
This bit turns ON during execution of commands that have completions or during abort processing.

Bit 1

Command Hold Completed (HOLDL)

This bit turns ON when command hold processing has been completed. Refer to Chapter 5 Motion
Commands
for details on command timing charts.
OFF: Command hold processing not completed
ON: Command hold completed

Bit 3

Command Error Occurrence (FAIL)

This bit turns ON if motion command processing was not completed normally.
If motion command execution ends in an error, moving axes will be stopped. Refer to Chapter 5
Motion Commands
for details on command timing charts.
OFF: Normal completion
ON: Abnormal completion

Bit 8

Command Execution Completed (COMPLETE)

This bit turns ON when motion command processing was completed normally. Refer to Chapter 5
Motion Commands
for details on command timing charts.
OFF: Normal execution not completed
ON: Normal execution completed

IW††0A

Motion Subcommand Response Code

Range

Unit

0 to 5

Stores the code of the motion subcommand that is being executed.
This is the motion subcommand code that is currently being executed, so it is the same as the Motion Subcommand (setting
parameter OW††0A).