Axis motion parameters (sorted by register) – Yaskawa MP2200 Machine Controller User Manual

Page 24

Advertising
background image

xxiv

„

Axis Motion Parameters (Sorted by Register)

Register

Variable Name

Comments

IWxx00

MonitorMask

Drive status mask

IBxx000

Monitor.PowerUp SeqDone

Motion controller ready

IBxx001

Monitor.ServoOn

Servo is energized.

IBxx002

Monitor.ServoBusy

System is busy.

IBxx003

Monitor.ServoReady

Servo is ready.

IWxx01

Alarm.OutOfRangeParameter

Parameter number that is over range

ILxx02

Warning.AllMask

Warning mask

IBxx020

Warning.FollowingError

Following error warning

IBxx021

Warning.DynamicParameterOutOf-
Range

Dynamic parameter out of range warning

IBxx022

Warning.StaticParameterOutOfRange

Static parameter out of range warning

IBxx023

Warning.Mlink

Servo warning

IBxx024

Warning.InvalidCommand

Command Setting Error

IBxx026

Warning.PositiveOvertravel

Positive overtravel warning

IBxx027

Warning.NegativeOvertravel

Negative overtravel warning

IBxx028

Warning.ServoNotEnabled

Servo not energized warning

IBxx029

Warning.Communication

Servo communication warning

ILxx04

Alarm.AllMask

Alarm mask

IBxx040

Alarm.NetworkServo

Servo alarm

IBxx041

Alarm.NegativeOvertravel

Positive overtravel alarm

IBxx042

Alarm.PositiveOvertravel

Negative overtravel alarm

IBxx043

Alarm.PositiveSoftLimit

Positive software limit alarm

IBxx044

Alarm.NegativeSoftLimit

Negative software limit alarm

IBxx045

Alarm.ServoNotEnabled

Servo OFF alarm

IBxx046

Alarm.PositionCompletionTimeOut

Positioning timeout alarm

IBxx047

Alarm.PositionValueOutOfRange

Positioning out of range alarm

IBxx048

Alarm.SpeedOutOfRange

Speed out of range alarm

IBxx049

Alarm.FollowingError

Following error exceeded alarm

IBxx04A

Alarm.FilterTypeChanged

Filter type changed while in motion alarm

IBxx04B

Alarm.FilterTimeChanged

Filter time constant changed while in motion alarm

IBxx04D

Alarm.NotHomed

Zero point not set alarm

IBxx04E

Alarm.HomingWhileMoving

Zero point set while in motion alarm

IBxx04F

Alarm.ServoParameterOutOfRange

Servo parameter alarm

IBxx050

Alarm.ServoCommunicationTimeout

Servo communication synchronization alarm

IBxx051

Alarm.ServoCommunication

Servo communication alarm

IBxx052

Alarm.ServoCommandTimeout

Servo command timeout alarm

IBxx053

Alarm.ABSEncoderOverrange

Absolute encoder number of rotations exceeded alarm

IWxx08

Command.GetValue

Servo command response

IWxx09

Command.Status

Servo command status mask

IBxx090

Command.Busy

Servo command busy

IBxx091

Command.Hold

Servo command holding

IBxx093

Command.Fail

Servo command failed

IBxx098

Command.Complete

Servo command complete

IWxx0A

Command2.GetValue

Servo Command2 response

IWxx0B

Command2.Status

Servo Command2 status mask

IBxx0B0

Command2.Busy

Servo Command2 busy

IBxx0B3

Command2.Fail

Servo Command2 Failed